** THE MACHINE HAS 2 YEARS OF WARRANTY, FREE TRAINING (ENG, SPA, PORT) WITH A CERTIFIED PERSON BY IBRAMED, AND WITH YOUR PURCHASE WE CAN MANAGE A BAILMENT AGREEMENT WHENEVER YOU NEED IT **
The Heccus Turbo equipment is an innovative platform of combined therapies for body aesthetic treatments, with therapeutic modalities of high-power ultrasound with flat transducer, Aussie Current, Polarized Current, and High Voltage Current.
THE GREATEST POWER ON THE MARKET WITH 72 WATTS!!
The Heccus Turbo features ultrasonic energy delivered in three-dimensional form with the highest power on the market, at 72 Watts, and the largest effective radiation area of 24 cm².
Current Australian exclusive
The Aussie current is the evolution of therapeutic currents, being exclusive to Ibramed and indicated for various treatments with the aim of muscle strengthening, analgesia, and lymphatic drainage.
8 Channels of chains
The Heccus Turbo features 8 output channels for Australian current and 2 channels for polarized and high voltage currents;
Super Pulsed Exclusive Mode
For greater efficiency, the Heccus Turbo features a 75% super pulsed mode, to deliver the ultrasound energy in a fractional way, but generate the necessary heat to obtain the results.
TECHNOLOGY: Duo system
It has Duet System technology, which allows different treatments in more than one region of the body at the same time, reducing treatment session time and optimizing results.
Maneral: Two in one
Ultrasound allows automatic adjustment of 1.1 MHz and 3.3 MHz frequencies in the same applicator, without the need to change the transducer for therapy.
Treatment optimization
It has protocols that guide the treatment according to the indications for use and the therapeutic objective, therefore, the system guides the appropriate treatment modality.
Exclusive technique
Unique on the market with anodized crystals that lead to greater effectiveness of electric currents in the treatment area, in addition to allowing the unique electrodynamic technique of the transducer, which is a differential to optimize treatments with therapeutic currents in large areas of the body!!
INDICATIONS
- Cellulitis
- localized fat
- sagging skin
- Plastic surgery postoperative
- muscle flaccidity
- Lymphatic drainage
- body modeling
Application techniques:
Heccus Turbo has optimized protocols and is easy to operate. Simply select the therapeutic target and the system will direct you to the appropriate treatment modality.
High power ultrasound
Ultrasound at frequencies of 3.3 MHz and 1.1 MHz, allowing effective treatment even in thicker adipose tissue. It has 3 ultrasound emitters with ERA – effective radiation area – of 8cm² (totaling 24cm²), with 24W each and maximum output power of 72W, promoting greater therapeutic effect and shorter session time.
The Heccus Turbo also features continuous, pulsed, and super pulsed modes, as well as a lightweight, ergonomic transducer. And it associates thermal and mechanical effects, which produce vasodilation and increased tissue viscoelasticity, cavitation, mechanotransduction of signals, lipolysis, angiogenesis, and thixotropic effect, among others. In this modality, only the ultrasound transducer and the gel with or without active ingredients are used.
Australian Current
Aussie is a burst-modulated medium frequency alternating therapeutic current. It offers two frequency possibilities: 1KHz and 4KHz, which allows selecting the frequency according to the therapeutic objective, being 1KHz for muscle strengthening and toning, while the 4KHz frequency is for lymphatic drainage and analgesia.
The Aussie current features continuous, synchronous, sequential, and reciprocating output modes, plus a short duration burst (2ms on 1KHz current and 4ms on 4KHz current), making the stimulation delivered more efficient compared to other therapeutic electric currents.
In this modality, the Heccus Turbo allows the static technique with electrodes (8 output channels) or the dynamic technique (using a transducer), depending on the chosen treatment protocol.
Polarized current
Biased is a single-phase pulsed current that flows in only one direction. Its therapeutic application is intended for dynamic and static iontophoresis (permeation of assets by electro-repulsion) associated with the polar effects of current. The current contemplates positive and negative modes.
In this modality, the Heccus Turbo allows the static technique with electrodes (2 output channels) or the dynamic technique (using a transducer and dispersive electrode), depending on the chosen treatment protocol.
High voltage current
High-voltage current, also known as high-voltage pulsed current (CPAV), or high-voltage electrical stimulation (HEAV), is a current with twin pulses of high amplitude and short duration. Its waveform is monophasic (current flows in only one direction). The high voltage causes a decrease in skin resistance, making the current comfortable and tolerable. It offers continuous and synchronous output modes.
In this modality, the Heccus Turbo allows the static technique with electrodes (2 output channels) or the dynamic technique (using a transducer and dispersive electrode), depending on the chosen treatment protocol.
Three-dimensional sonophoresis
This therapeutic modality combines high-power ultrasound with Aussie current in the same therapy time.
When selecting the desired protocol, it is enough to select the value corresponding to the number of applicators that fit in the region to be treated, and the calculation of the treatment time is given automatically by the equipment. To calculate the ultrasound intensity, simply measure the fat layer with an audiometer and enter the value in centimeters on the screen. The adjustment of the ultrasound intensity and the ultrasound mode (continuous or pulsed) is automatic.
In this mode, only the transducer and the neutral or active conductive gel are used.
Sonoiontophoresis
This therapeutic modality associate high-power ultrasound with polarized current in the same therapy time.
When selecting the desired protocol, it is enough to select the value corresponding to the number of applicators that fit in the region to be treated, and the calculation of the treatment time is given automatically by the equipment. To calculate the ultrasound intensity, simply measure the fat layer with an adipometer and enter the value in centimeters on the screen. The adjustment of the ultrasound intensity and the ultrasound mode (continuous or pulsed) is automatic. The product polarity must also be set to P+ or P-.
In this mode, the transducer, conductive gel with defined polarity active ingredients, yellow dispersive cable, aluminum plate electrode with vegetable cloth, and alligator clip adapter are used.
Sonoelectroporation
This therapeutic modality associate high-power ultrasound with high-voltage current at the same time of therapy.
When selecting the desired protocol, it is enough to select the value corresponding to the number of applicators that fit in the region to be treated, and the calculation of the treatment time is given automatically by the equipment. To calculate the ultrasound intensity, simply measure the fat layer with an adipometer and enter the value in centimeters on the screen. The adjustment of the ultrasound intensity and the ultrasound mode (continuous or pulsed) is automatic.
In this mode, the transducer, active conductive gel, yellow dispersive cable, aluminum plate electrode with vegetable cloth, and alligator clip adapter are used.
The application of treatments should only be carried out by qualified and duly qualified professionals.
Indications:
individual therapies
Therapeutic ultrasound
- Improved healing after plastic or reconstructive surgery;
- Localized fat reduction;
- cellulitis;
- Improves the quality and firmness of the skin;
- Hydrolipoclasia.
Australian Current
- Strengthening, hypertrophy, and muscle toning;
- Increased local blood circulation;
- Pain relief after plastic or reconstructive surgery;
- Increased lymphatic and vascular drainage;
- cellulitis;
- Localized fat reduction (electro-lipolysis).
Polarized current
- Active permeation (iontophoresis);
- Increased local circulation.
High voltage current
- Active permeation (electroporation);
- Healing of ulcers and wounds;
- Increased local blood circulation;
- Pain relief after plastic or reconstructive surgery;
- Increased lymphatic and vascular drainage.
Combination therapies
Three-dimensional sonophoresis (therapeutic ultrasound + Aussie current)
- Localized fat associated with muscle toning;
- Localized fat associated with lymphatic drainage;
- Gynoid lipodystrophy (cellulite) associated with muscle toning;
- Gynoid lipodystrophy (cellulitis) associated with lymphatic drainage;
- Improved healing associated with analgesia in the postoperative period of plastic or reconstructive surgery;
- Improves the quality and firmness of the skin.
Sonoelectroporation (therapeutic ultrasound + high voltage current)
- Localized fat associated with electroporation of active ingredients;
- Gynoid lipodystrophy (cellulite) associated with electroporation of active ingredients;
- Improved healing associated with analgesia in the postoperative period of plastic or reconstructive surgery.
Sonoiontophoresis (therapeutic ultrasound + polarized current)
- Localized fat associated with active ionization;
- Cellulite is associated with active ionization.
Technical characteristics:
- Automatic bivolt: 100 to 240 V | 50/60hz;
- Ultrasound: 1.1 MHz (±10%) / 3.3 MHz (±10%) frequency / Effective Radiation Area (ERA): 24 cm² / Maximum output power: 72 W (± 20%) / Modes: continuous or pulsed;< /li>
- Australian Current: 1 or 4 kHz (±10%) / Burst Duration: 2 or 4 ms (±10%) / Burst Frequency : 01-120 Hz (±10%);
- Polarized current: frequency 15KHz (± 10%) / Polarity: positive or negative;
- High Voltage Current: 1-300V maximum output current/Polarity: Positive or Negative/Frequency: 1-250Hz.